F2.48
output delay time of relay 1
F2.49
output delay time of relay 2
Same as the Y output delay time of [F2.47].
F2.50
F2.51
Virtual vX1terminal function selection
F2.52
Virtual vX2terminal function selection
F2.53
Virtual vX3terminal function selection
F2.54
Virtual vX4terminal function selection
Virtual vX1-vX4 are the same in terms of function with the X1-X7 on the control panel, which can be used as the
multi-functional digital input; please refer to [F2.00-F2.06] for detailed information.
F2.55
vX terminal valid state source
LED "0"digit: virtual vX1
LED"00"digit: Virtual vX2
LED "000"digit: Virtual vX3
LED"0000"digit: Virtual vX4
0: internal connection to the virtual vYi; vYi state to decide whether vXi valid (i = 1- 4) or not.
1: set by function code [F2.56].
Virtual vX1 ~ vX4 input terminal status can be set in two ways, selected by [F2.55]; when the state of vX1 ~ vX4 is
determined by the state of virtual vY1 ~ vY4, whether vX1 ~ vX4 is valid or not is depend on vY1 ~ vY4 output, and vX1
~ vX4 and vY1 ~ vY4 are tied together.
When selecting state of vX1 ~ vX4 is set by the function code, the corresponding input terminals can be set respectively
through the function code [F5.56]
Virtual vX terminal function code
F2.56
setting valid state
LED "0"digit: virtual vX1
LED"00"digit: Virtual vX2
LED "000"digit: Virtual vX3
LED"0000"digit: Virtual vX4
0: vXi invalid.
1: vXi valid. (i = 1-4)
F2.57
VS terminal function selecting(as X)
F2.58
AI terminal function selecting(as X)
F2.59
AS terminal function selecting(as X)
Analog input terminal X and function selection is the same as X1-X7, for detailed description see [F2.00-F2.06].
When the analog terminal input X, high electrical level when the analog voltage exceeds 7V; low electrical level when
Setting range:0.0-360.0s
Reserved
Setting range:0-47
Setting range:0000-1111
Setting range:0000-1111
Setting range:0-47
105
FUNCTION PARAMETER SPECIFICATION
Factory default:0
Factory default:0
Factory default:0000
Factory default:0000
Factory default:0