AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
Output terminal can be selected to act or not act in automatic reset process. Details refer to [F2.29-F2.31].
Malfunction auto-reset interval: It defines waiting time before resetting after fault.
Note: 1: Only valid for fault of OL, OC, system abnormity, under voltage. Not valid for other faults.
2: Can't reset before dealing with malfunction.
Attention: Please use this function carefully in occasions that can't start with load, or that needs alarm
immediately when there's no output.
FA.24
FA.25
Malfunction types
Malfunction running
FA.26
frequency
FA.27
Malfunction output voltage
FA.28
Malfunction output current
FA.29
Malfunction bus voltage
Malfunction module
FA.30
temperature
FA.31
Malfunction machine state
Malfunction input terminal
FA.32
state
Malfunction output terminal
FA.33
state
FA.34
The last 1 malfunction types
The last 1 malfunction
FA.35
running frequency
The last 1 malfunction output
FA.36
voltage
The last 1 malfunction output
FA.37
current
The last 1 malfunction bus
FA.38
voltage
The last 1 malfunction
FA.39
module temperature
FA.40
The last 1 machine state
reserved
Please see malfunction code table
0.00-max frequency
0-1500V
0.1-2000.0A
0-3000V
0-100℃
LED "0" digit: run direction
0: FWD
1: REV
LED "00" digit: run state
0:stop
1:stable speed
2:ACC
3:DEC
LED "000" digit: reserved
LED "0000" digit: reserved
See input terminal chart
See output terminal chart
Please see malfunction code table
0.00-max frequency
0-1500V
0.1-2000.0A
0-3000V
0-100℃
LED "0" digit: run direction
0: FWD
1: REV
LED "00" digit: run state
0:stop
1:stable speed
2:ACC
3:DEC
LED "000" digit: reserved
132
FUNCTION PARAMETER SPECIFICATION
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents