Veichi AC100-T3-1R5G Manual page 202

High-performance vc frequency inverter
Table of Contents

Advertisement

AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
4.5 Related Parameters Settings
Please set parameters according to actual needs. Related parameters are listed as follows:
4.6 Wiring Precautions
1, PG card signal lines and power lines should be separated; no parallel wiring.
2, To avoid the encoder signal interference, please use shielded cable as the signal line of PG card.
3, The encoder shielded cable should be connected to the ground (or the inverter PE terminal), single-grounded is even
better to avoid signal interference.
4.7 Overall Wiring Diagram
Function code
F0.00
F5.15
F5.16
PG01-ABZ-05-C1
A+ A- B+ B- Z+ Z- PE
PG
...
Name
Control mode
Type of rotary encoder
Numbers of pulse every circle
L1 L2 L3
R S T
U V W
Monitor device
M
3 ~
199
Appendix
fo=fi/508
fo=fi/510