Veichi AC100-T3-1R5G Manual page 157

High-performance vc frequency inverter
Table of Contents

Advertisement

AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
0 speed hold torque
F1.28
time
Power off restart
F1.29
action selection
Power off restart
F1.30
waiting time
Terminal running
F1.31
protection selection
JOG running
F1.32
frequency setting
F1.33
JOG ACC time
F1.34
JOG DEC time
F1.35
Jump frequency
Jump frequency
F1.36
range
Quantum Digital Terminal Parameter Group
NO.
Function description
Multifunction
F2.00
terminal 1(X1)
If set between 0.0-5999.9s, 0 speed
hold torque keep setting time. If set
6000.0s, 0 speed hold torque no time
limit
0: Invalid
1: Valid
0.00-120.00s
LED "0" digit: run command selection
when electrifying
0: Terminal running order invalid when
electrifying
1: Terminal running order valid when
electrifying
LED "10" digit: when switching the run
command given channel
0: invalid
1: valid
0.00-Max frequency
0.01-650.00s
0.01-650.00s
0.00-Max frequency
0.00-Max frequency
Range of settings and definition
0: No function
1: FWD
2: REV
3: 3-line running control
4: FWD JOG
5: REV JOG
6: Free stop
input
7: Emergency stop
8: Malfunction reset
9: External fault input
10: Frequency UP
11: Frequency DW
12: UP/DW clear
13: Speed torque control clear
(UP/DOWN clear o)
14: Torque control banned
154
Appendix
0.0s
0
0.50s
11
5.00Hz
10.00s
10.00s
0.00Hz
0.00Hz
Factory
Address
Feature
default
1
0x11C
0x11D
0x11E
0x11F
0x120
0x121
0x122
0x123
0x124
0x200