AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
Commissioning Debugging Guide
Confirm power connected correctly
and motor wiring and electrifying correctly
Set according to the motor nameplate
and wiring mode F5.01-F5.06
Confirm motor direction, if REV direction, exchange
any two phase motor wires after power off or set F0.16
parameter and change rotary direction.
No
static self study, set F5.12 = 2,press FWD
and wait the completion of self study
VF control mode
set F0.01=1
select VF control mode
Set running frequency
given channel F0.03=0
Set running frequency F0.08
Start
Press JOG/REV to jog running
Yes
If motor can
disengage load
rotary self study, set F5.12 = 1,press FWD
and wait the completion of self study
VC control mode
Select VF/VC control mode
Set F0.01=0
select speed control
Set running command to rated channel F0.02=0
Press FWD and running
Press STOP/RESET to stop
Chart 4-20: Commissioning Debugging Guide
50
BASIC OPERATION AND TRIAL RUN
set F0.01=0
select VC control mode
Set given torque F7.00 and torque direction
F7.02 and torque limit F7.03/F7.04, set torque
control speed limit F7.06-F7.08
End
set F0.00=1
select torque control