Veichi AC100-T3-1R5G Manual page 66

High-performance vc frequency inverter
Table of Contents

Advertisement

AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
Diagnose Process For Over Voltage
Reduce power voltage
into fixed range
Clear short circuit
Stop motor and restart.
Or DC braking,then
start(F1.00:1). Or speed
track start(F1.00:2)
Maybe inverter fault or
misact.Plese seek for
technic support
Reduce
ACC over
DCC over
voltage(OU1)
voltage(OU2)
no
Fower votage in fixed range or not
yes
yes
yes
Phase or earth short cirsuit bwteen U/V/W and motor
no
no
yes
Whether it stops while restart the motor
no
no
Whether act while load suddently changes to"0"
no
no
no
Whether DC circuit voltage of main loop is above protection value while act
yes
yes
no
Whether act while
Can prolong DCC time or not
suddently stop ACC
yes
no
ACC time can be
prolong or not
no
yes
Load intertia can be reduced or not
no
no
Whether used braking unit or DC braking function
yes
yes
Please check braking unit and seek for technic support
FAULT DIAGNOSES AND PROCESSING
Stop state over
Constant speed
voltage(OU4)
over voltage(OU3)
yes
no
no
no
yes
yes
no
yes
no
yes
63
yes
prolong
Use braking unit or DC
braking function