3.2 Dealing Methods for Inverter after Long-term Storage

If the inverter storage time is over one year, the aluminum capacitor in the inverter must be pre-charged again and
make sure the aluminum capacitor characteristic recovered before installation. For specific method, please follow the
grads in the chart below and give more than 30 mins corresponding proportional voltage for every grad when the
inverter is no-load.
If the input voltage of one grad is at the critical point of contactor, fan or other equipments, please increase or reduce
the corresponding input voltage for the grad to avoid any related components working under critical state.

3.3 Stable Running Environment for Inverter

Installation environment is very important to maximize the performance of this product and maintain long-term function,
so please install the product in the environment as required in the following chart.
Environment
Installation site
Indoor without direct sunshine
Operating
-10 ~ +40
temperature
-10 ~ +45
Storage temperature
-20 ~ +60
Environment humidity
Please install the inverter in place as follows:
Surroundings
Altitude
<1000m
<10~20Hz:9.8m/s
Vibration
<20~55Hz:5.9m/s
Installation and
cooling
Chart 3-1:AC100 Series Inverter Running Environment Condition
Chart 3-1: Dealing Methods for Inverter after Long-term Storage
(hanging type)
(cabinet type)
<95%RH, no condensation
Place without oil mist, corrosive gases, flammable gas, dust, etc.
Place where metal dust, oil, water would not get inside the inverter (please do not install
inverter on flammable material such as wood, etc).
Place without radioactive material or flammable material.
Place without poisonous gases or liquid.
Place with little salt corrosion.
Place without direct sunshine.
2
2
Inverter must be installed vertically and longitudinally, and it can't be installed horizontally.
Please independently install high heating equipments such as braking resistor and it can't be
installed in the same cabinet with inverter. Installation of high heating equipments at the air-in
port of the inverter is strictly prohibited.