4.3 Basic Operation

Parameter Initialization
Set F0.19=1, and the parameter initialization is completed. Operation details as follows:
Control Mode Selection of Motor 1
Here we set F0.00=0(AM VC without PG)as an example to introduce.
Start-up Mode Selections
Three start-up modes: 0: direct start-up, 1: braking firstly, then start by start-up frequency, 2: speed track and
start-up. Here we set F1.00=2(speed track and start-up) as an example:
Motor Parameter Setting
Set[F5.02](motor rated power),[F5.03](motor rated frequency),[F5.04](motor rated speed), [F5.05]
(motor rated voltage) according to the motor nameplate. Other parameter setting can be obtained by inverter
self-study.
Please refer to the following operation mode chart:
Chart 4-2: Parameter Initialization
Chart 4-3: Control Mode Selection of Motor 1
Chart 4-4: Start-up Mode Selections