Multi-Step, Plc Function And Swing Frequency Parameters - Veichi AC100-T3-1R5G Manual

High-performance vc frequency inverter
Table of Contents

Advertisement

AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
8.12 Multi-speed, PLC Function and Swing Frequency Parameters
FC.00
PLC multi-speed 1
FC.01
PLC multi-speed 2
FC.02
PLC multi-speed 3
FC.03
PLC multi-speed 4
FC.04
PLC multi-speed 5
FC.05
PLC multi-speed 6
FC.06
PLC multi-speed 7
FC.07
PLC multi-speed 8
FC.08
PLC multi-speed 9
FC.09
PLC multi-speed 10
FC.10
PLC multi-speed 11
FC.11
PLC multi-speed 12
FC.12
PLC multi-speed 13
FC.13
PLC multi-speed 14
FC.14
PLC multi-speed 15
It sets run frequency of 15 steps in PLC and multistep control.
Multi-speed control has priority only after JOG. When in multi-speed control, 4 multifunction input terminals are needed
to set as control terminals. Set details refer to [F2.00-F2.06].
Running speed of inverter is decided by the ON/OFF state of 4 control terminals and COM. The running and direction is
controlled by running signal and direction given by [F0.02]. ACC/DEC time default is ACC/DEC time 1 [F0.14], [F0.15].
ACC/DEC time can also be selected by ACC/DEC time selection terminal set by [F2.00-F2.06].
Multi speed terminal
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Setting range: 0.00-320.00Hz
Multi speed terminal
Multi speed terminal
3
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
FUNCTION PARAMETER SPECIFICATION
Multi speed terminal
2
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
138
Factory default: 10.00Hz
Factory default: 20.00 Hz
Factory default: 30.00 Hz
Factory default: 40.00 Hz
Factory default: 50.00 Hz
Factory default: 40.00 Hz
Factory default: 30.00 Hz
Factory default: 20.00 Hz
Factory default: 10.00 Hz
Factory default: 20.00 Hz
Factory default: 30.00 Hz
Factory default: 40.00 Hz
Factory default: 50.00 Hz
Factory default: 40.00 Hz
Factory default: 30.00 Hz
terminal
1
speed
ON
1X[FC.00]
OFF
2X[FC.01]
ON
3X[FC.02]
OFF
4X[FC.03]
ON
5X[FC.04]
OFF
6X[FC.05]
ON
7X[FC.06]
OFF
8X[FC.07]
ON
9X[FC.08]
OFF
10X[FC.09]
ON
11X[FC.10]
OFF
12X[FC.11]
ON
13X[FC.12]
OFF
14X[FC.13]
ON
15X[FC.14]

Hide quick links:

Advertisement

Table of Contents
loading