AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
FUNCTION PARAMETER SPECIFICATION
17: Multi steps terminal 3
18: Multi steps terminal 4
15 speeds would be realized by code combinations for multi-speed instruction; multi-speed command has priority
second only to jog command. See parameter details of multi steps and FC group of PLC.
19: ACC/DEC time selection terminal 1
20: ACC/DEC time selection terminal 2
4 ACC/DEC speeds would be realized by code combinations. ACC/DEC time selection terminal 1 is defaulted as valid
when not set parameter and terminal invalid. Details see [F1.18-F1.23].
21: ACC/DEC pause: In ACC/DEC process, if the terminal is valid, the inverter stops ACC/DEC and keeps the speed. It
is only valid when inverter is running. It is invalid for DEC stop.
ON
ON
ACC/DEC pause
ON
run order
give frequency
output frequency
pause
pause
ACC/DEC pause
22: PID control cancel: When [F0.03] is set as 8 and this terminal is valid, it can make PID function invalid; when the
given frequency of main frequency channel is changed to 0.00Hz. And when this terminal is invalid, the PID re-counts
the given frequency of main channel.
23: PID control pause: When PID given and this terminal is valid, it can make PID adjustment be invalid and keep
frequency not change. PID re-counts the given frequency of main channel.
24: PID trait switch When [F0.03] is set as 8 and this terminal is valid, [Fb.05] LED "0" digit-trait setting will be
changed. PID output trait back to [Fb.05] LED "0" digit-trait setting.
25: PID given switch 1
26: PID given switch 2
27: PID given switch 3
When PID controller given signal source [Fb.00] is set as 8, give signal source channel can be switched by this group of
terminals. Details see [Fb.00].
28: PID feedback switch 1
29: PID feedback switch 2
30: PID feedback switch 3
When PID controller feedback signal source [Fb.02] is set as 8, feedback signal source channel can be switched by this
group of terminals. Details refer to [Fb.02].
31: PLC pause: When [F0.03] is 9, this valid signal can make PLC pause and inverter output 0.00Hz. Inverter goes on
as before when this signal disappears. See parameter details of multi steps and FC group of PLC.
32: PLC restart: When [F0.03] is 9, this valid signal can make PLC start from the 1
step again at stop state or running.
st
See parameter details of multi steps and FC group of PLC.
33: Swing frequency input
Swing frequency control, if set to manual input, when the terminal is valid, the swing frequency function is valid, the
96