15
PUL input
Module
16
temperature 1
Module
17
temperature 2
F3.24
A01 output gain
F3.25
A01 output signal bias
A01 output gain: It is used for adjusting AO1 terminal output analog value.
A01 output signal bias: It is used for adjusting AO1 terminal 0 point of output signal.
Note: AO1 output terminal includes voltage output and current output. Please select K2,when used as 0-10V output;
Please select K1,when used as 0-20mA output. All is used as 0-10V output in factory default hardware setting.
F3.26
Corresponding to current
PUL input
Corresponding to current
module temperature 1
Corresponding to current
module temperature 2
Setting range: 25.0-200.0%
Setting range: -10.0-10.0%
FUNCTION PARAMETER SPECIFICATION
Min output corresponding
to PUL input lower limit
Min output corresponding
to 0 degree module
temperature 1
Min output corresponding
to 0 degree module
temperature 2
Reserved
111
Max output corresponding to
PUL input upper limit
Max output corresponding to
module temperature 1 is 100
degree
Max output corresponding to
module temperature 2 is 100
degree
Factory default: 100.0%
Factory default: 0.0%