Veichi AC100-T3-1R5G Manual page 100

High-performance vc frequency inverter
Table of Contents

Advertisement

AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
inverter starts swing frequency operation. See parameter [FC.49-FC.55]
34: Swing frequency pause
Swing frequency control, when the terminal is valid, the inverter output frequency maintains constant current. The
terminal command restores to swing frequency operation after revocation. See parameter [FC.49-FC.55]
35: Swing frequency reset
Swing frequency control, when the terminal is valid, the inverter runs with center frequency. The terminal command
restores to swing frequency operation after revocation. See parameter [FC.49-FC.55]
36: Frequency channel switch terminal 1
37: Frequency channel switch terminal 2
38: Frequency channel switch terminal 3
39: Frequency channel switch terminal 4
It is valid only when [F0.03] is set as 12. Main frequency input channel is selected by terminal. 4 terminals can be
combined to 0-11 which is corresponding to frequency input channels 0-11 of [F0.03]. Details refer to [F0.03].
40: Timer touch terminal valid when closed. Detail refers to [F2.25-F2.26].
41: Timer clear terminal valid when closed. Detail refers to [F2.25-F2.26].
42: Counter clock input terminal Detail refer to [F2.27-F2.28].
43: Counter clear terminal valid when closed. Detail refers to [F2.27-F2.28].
44: DC brake order: At stop state, it can start DC brake function. Details refer to [F1.09]. If input run order or JOG
order, DC braking will be stopped.
45: Pre-excitation order terminal: At stop state, it can start pre-excitation function. If inputting run or JOG order,
pre-excitation order would be cancelled.
46: Reserved
47: Reserved
F2.07
F2.08
X1-X4 terminal trait selection
F2.09
X1-X4 input terminal filter time
X1-X4 terminal trait selection: set multi-function input terminals X1, X2, X3, X4 features.
LED "0"digit: X1 terminal
0: On valid
1: Off valid
LED"00"digit: X2 terminal
0: On valid
Reserved
Setting range: 0000-1111
Setting range: 0.000-60.000s
97
FUNCTION PARAMETER SPECIFICATION
Factory default: 0000
Factory default: 0.010s