AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
1: Off valid
LED "000"digit: X3 terminal
0: On valid
1: Off valid
LED"0000"digit: X4terminal
0: On valid
1: Off valid
X1-X4 input terminal filter time: When input terminal state changes, only if changed state keeps after filter time setting,
it is considered as valid terminal state change. Otherwise, it keeps last state to effectively avoid misact caused by
disturbance.
F2.10
X5-X7 terminal trait selection
F2.11
X5-X7 input terminal filter time
Same as above
F2.12
Terminal control mode
The parameter defines the 4 different ways of controlling the inverter operation by external terminals.
0:2-line 1 Run and direction in 1.Factory set is X1(FWD), X2(REV) terminals decide motor forward or reverse.
K1
0
1
0
1
1:2-line 2 Run and direction is separate. FWD terminal X1 is run terminal. FWD terminal X2 state decides direction.
K2
K1
0
1
1
0
2:3-line 1 Xi is stop run terminal. Run order is decided by FWD terminal X1. Direction is controlled by REV terminal X2.
Xi is valid input.
Setting range: 0000-1111
Setting range: 0.000-60.000s
Setting range: 0-3
run order
K2
0
stop
0
FWD
1
REV
1
COM
0: 2-line 1
run order
stop
0
0
FWD
1
REV
stop
1
frequency inverter
X1
K1
FWD order(run while close)
X2
K2
REV order(run while close)
COM
common input port
frequency inverter
K1
X1
FWD order(run while close)
K2
X2
REV order(run while close)
COM
common input port
1: 2-line 2