AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
F2.14
Reserved
F2.15
Reserved
PUL input min
F2.16
frequency
PUL min frequency
F2.17
corresponding
setting
PUL input max
F2.18
frequency
PUL max frequency
F2.19
corresponding
setting
F2.20
PUL filter time
PUL cut-off
F2.21
frequency
UP/DW terminal
F2.22
frequency control
mode
ACC/DEC speed of
F2.23
UP/DW terminal
frequency
F2.24
Reserved
F2.25
Timer time of unit
F2.26
Timer setting
F2.27
Counter max value
Counter setting
F2.28
value
F2.29
Output terminal (Y)
0.0-50.00kHz
0.00-100.00%
0.0-50.00kHz
0-100.00%
0.00s-10.00s
0.000-1.000kHz
0: Off electricity storage
1: Off electricity does not storage
2: Valid in running, clear zero at stop
0.01~50.00Hz/s
0: Second
1: Minute
2: Hour
0~65000
0~65000
0~65000
0: No output
1: FWD Running
2: REV Running
3. Fault trip alarm 1(alarm when fault
self-recover)
4: Fault trip alarm 2(no alarm when
fault self-recover)
5: Fault retrying
6: External fault stop
7: Under voltage
8: Finish ready for running
9: Output frequency level test 1(FDT1)
157
0.00kHz
0.00%
50.00kHz
100.00%
0.10s
0.010kHz
0
0.50Hz/s
0
0
1000
500
0
Appendix
0x20E
0x20F
0x210
0x211
0x212
0x213
0x214
0x215
0x216
0x217
0x218
0x219
0x21A
0x21B
0x21C
0x21D