Veichi AC100-T3-1R5G Manual page 121

High-performance vc frequency inverter
Table of Contents

Advertisement

AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
static self study or no self study is ok. If no self study, please do set right parameters [F5.01-F5.06]
3. If user know the right parameter. User can set [F5.01-F5.11] directly.
4. Ensure stop state before starting self study, otherwise, self study can't be normal.
5. When [F5.12] is 1, if there is over voltage or over current in self study process, ACC/DEC time [F0.14, F0.15]
can be prolonged.
6. If static self study is not successful, alarm E.tE1 fault. If rotary self study is not successful, alarm E.tE2 fault.
F5.13-F5.14
F5.15
Speed feedback or encoder type
LED "0" digit: encoder type: set encoder type according to the encoders actually selected.
0: Normal ABZ encoder
1: Resolver
2: UVW encoder
3: wire-saving UVW encoder
LED "00" digit: encoder direction: When motor speed direction and encoder speed direction is inconsistent, switch
direction by setting the parameter.
0: same direction;
1: opposite direction
LED "000" digit: disconnection detection: when the break detection is turned on, the inverter would report encoder
failure and stop when encoder disconnection is found.
0: Close
1: Open
LED "0000" digit: PG card selection: Select the encoder signal source; AC100 supports three motor speed signal
ports.
0: PG port 1
1: PG port 2
2: PUL pulse input
F5.16
Photoelectric encoder lines
Photoelectric encoder lines: used to set output pulse of speed feedback sensor per week; please set correctly
according to the sensor specification.
F5.17
PG line-break detection time
PG line-break detection time: used to confirm sensor disconnection delay time when the sensor break detection
setting is valid; set 0sec as the off function of line-break detection.
F5.18
Resolver poles
Resolver poles: Set according to actual selection of resolver, usually 2-pole resolver
Reserved
Setting range: 0000-2113
Setting range: 0-60000
Setting range: 0.100-60.000s
Setting range:2-128
118
FUNCTION PARAMETER SPECIFICATION
Factory default: 0000
Factory default: 1024
Factory default: 0.000s
Factory default:2