Veichi AC100-T3-1R5G Manual page 57

High-performance vc frequency inverter
Table of Contents

Advertisement

AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
asynchronous motors or synchronous motor torque control debugging procedure
Set start and stop command, using local keyboard to set frequency and
command channel related function code F0.02,F0.03,F0.09,F0.14,F0.15;
Set motor parameter F5.01-F5.06,F8.00, and set F5.15-F5.19 according
to encoder; set speed mode to debug F0.01=0
Speed mode pass or not ?
torque control debugging , set F0.01=1;
set torque command parameter:F7.00,F7.02;
torque control debugging
Debugging ends and set other parameters
according to the users' requirements
F0.00=0
F0.00=2
F0.00=7
Yes
Normal or not?
Yes
Chart 4-24 motor torque control debugging procedure
BASIC OPERATION AND TRIAL RUN
No
re-debug speed
control mode
No
cooperate with speed ring parameter
(F6.00-F6.09), current ring parameter
(F6.16-F6.19) adjustment
54