Veichi AC100-T3-1R5G Manual page 181

High-performance vc frequency inverter
Table of Contents

Advertisement

AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
The last malfunction
FA.41
input terminal state
The last malfunction
FA.42
output terminal state
The first two
FA.43
malfunction types
The first three
FA.44
malfunction types
PID Process Control Parameter Group
NO.
Function description
PID given signal
Fb.00
source
Keyboard digit given
Fb.01
PID
PID feedback signal
Fb.02
source
Fb.03
Feedback signal gain
Feedback signal max
Fb.04
measuring range
See input terminal chart
See input terminal chart
Please see malfunction code table
Please see malfunction code table
Range of settings and definition
0: Keyboard digit PID given
1: Keyboard potentiometer given
2 : Terminal VS voltage analog given
3: Terminal AI analog given
4: Terminal AS current analog given
5: Terminal PUL pulse signal given
6: RS485 communication given
7: Optional card
8: Terminal selection
9: VS3 (extended)
0.00~100.0%
0: Keyboard digit PID feedback
1: Keyboard potentiometer feedback
2 :Terminal VS voltage analog feedback
3: Terminal AI analog feedback
4: Terminal AS current analog feedback
5: Terminal PUL pulse signal feedback
6: RS485 communication feedback
7: Optional card
8: Terminal selection
9: VS3 (extended)
0.00~10.00
0~100.0
178
--
×
--
×
--
×
--
×
Factory
Feature
Address
default
0
50.0%
2
1.00
100.0
Appendix
0xA29
0xA2A
0xA2B
0xA2C
0xB00
0xB01
0xB02
0XB03
0xB04

Hide quick links: