Example 2: cases requires the inverter forward run after 60s delay when the the inverter electrified, as follows:
Set F0.02 = 1 Run command source terminal control, F2.12 = 2 Three-line control 1;
Set F2.26 = the timer counts 60s;
Set F2.51 = 1 vX1 terminal function input, run forward;
Set F2.52 = 3 vX2 terminal function input, three-line running control (Xi);
Set F2.53 = 40 vX3 terminal function input, timer trigger;
Set F2.55 = 0110 vX2 and vX3 active source is determined by "0"digit" and
"00"digit of F2.56;
Set F2.56 = 0110 vX2, vX3 setting is valid;
Set F2.61 = 21 vY1 output when the timer reaches.
F2.56"000" digit
Running
command
=1
=0
Stop command
Note: It can be seen from the chart when using a conventional method requires access to two actual external X
terminal, but if using virtual terminal, access to external actual terminal is not needed.
vY1 connecting to vX1
F2.55 "0" digit setting
F2.61
vY1
=8
vY1 output
2 line control 1 virtual terminal control
time reach vY1
vX3 triggers timer
output F2.61
to count F2.53
vX3
=40
state
three-line
control(F2.52)
F2.56"00" digit
vX2
=1
state
=0
Inverter
=0
=1
vX1
vX1
Inverter
Running control
vY1 connecting to
vX1 F2.55 "0" digit
=0
=1
=21
vY1
state
Stop control
=3
107
FUNCTION PARAMETER SPECIFICATION
F2.51
FWD running
=1
=0
F2.51
FWD running
=1
vX1
=0
state
Stop running
(stop when off)