Braking current
F1.04
before start
Braking time before
F1.05
start
Speed tracking
F1.06
stability waiting time
F1.07
Stop mode
DC braking initial
F1.08
frequency
F1.09
DC braking current
DC braking waiting
F1.10
time
F1.11
DC braking duration
F1.12
Reserved
ACC/DEC mode
F1.13
selection
Start ACC rate of S
F1.14
curve
ACC slope
F1.15
increment of S curve
F1.16
Reserved
F1.17
Reserved
F1.18
ACC time 2
F1.19
DEC time 2
F1.20
ACC time 3
F1.21
DEC time 3
F1.22
ACC time 4
F1.23
DEC time 4
Emergency stop
F1.24
DEC time
FWD&REV dead
F1.25
time
F1.26
Min output frequency
F1.27
0 speed hold torque
0~150.0%
0.0~60.0s
0.00~60.00s
0: DEC to stop
1: Free stop
0.00~50.00Hz
0.0~150.0%
0.0~60.0s
0.0~60.0s
LED "0" digit: ACC/DEC time base
0: max frequency
1: fixed frequency
LED "00" digit: ACC/DEC mode
0: Beeline
1: S Curve
LED "000" digit: reserved
LED "0000" digit: reserved
20.0%-100.0%
20.0%-100.0%
0.01-650.00s
0.01-650.00s
0.01-650.00s
0.01-650.00s
0.01-650.00s
0.01-650.00s
0.01-650.00s
0.0~120.0s
0.00-60.00Hz
0.0-150.0%
153
0.0%
0.0s
0.5s
0
0.00Hz
0.0%
0.0s
0.0s
0000
50.0%
50.0%
10.00s
10.00s
10.00s
10.00s
10.00s
10.00s
10.00s
0.0s
0.50Hz
Model set
Appendix
0x104
0x105
0x106
0x107
0x108
0x109
0x10A
0x10B
0x10C
0x10D
0x10E
0x10F
0x110
0x111
0x112
0x113
0x114
0x115
0x116
0x117
0x118
0x119
0x11A
0x11B