AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
Fb.05
PID control selection
Fb.06
PID preset output
PID preset output
Fb.07
running time
Fb.08
Proportional gain P
Fb.09
Integral time I
Fb.10
Differential gain D
Fb.11
Sample cycle
PID control deviation
Fb.12
limit
Fb.13
Reserved
Feedback wire break
Fb.14
detection time
Feedback wire break
Fb.15
action selection
Wire break alarm
Fb.16
upper limit
Wire break alarm
Fb.17
lower limit
Multi-Speed, PLC Function and Swing Frequency Parameter Group
NO.
Function description
FC.00
PLC Speed 1
FC.01
PLC Speed 2
FC.02
PLC Speed 3
FC.03
PLC Speed 4
FC.04
PLC Speed 5
FC.05
PLC Speed 6
LED "0"digit: feedback feature selection
0: Positive feature
1: Negative feature
LED "10"digit: PID adjustment direction
selection
0:reverse forbidden
1:reverse allowed
LED "100"digit: alignment selection
0: not centre align
1: centre align
LED "1000"digit: reserved
0.00~100.0%
0.0~6500.0s
0.00~100.00
0.01~10.00s
0.00~10.00s
0.01~100.00s
0.0~100.0%
0.0~120.0s
0: Go on PID operation without alarm
1: Stop and alarm malfunction
2: Go on PID operation and output
alarm signal
3: Run at the current frequency and
output alarm signal
0.0~100.0%
0.0~100.0%
Range of settings and definition
0.00-320.00Hz
0.00-320.00Hz
0.00-320.00Hz
0.00-320.00Hz
0.00-320.00Hz
0.00-320.00Hz
179
0100
100.0%
0.0s
1.00
0.10s
0.00s
0.10s
0.0%
1.0s
0
100.0%
0.0%
Factory
Feature
Address
default
10.00Hz
20.00Hz
30.00Hz
40.00Hz
50.00Hz
40.00Hz
Appendix
0xB05
0xB06
0xB07
0xB08
0xB09
0xB0A
0xB0B
0xB0C
0xB0D
0xB0E
0xB0F
0xB10
0xB11
0xC00
0xC01
0xC02
0xC03
0xC04
0xC05