816f0108-0a01ffff • 816f010c-2581ffff
816f0108-0a01ffff
[PowerSupplyElementName] has returned to OK status.
Explanation: IMM has detected that Power Supply 1 has returned to a normal operational status.
May also be shown as 816f01080a01ffff or 0x816f01080a01ffff
Severity: Info
Alert Category: Critical - Power
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0087
SNMP Trap ID: 4
Automatically notify Support: No
User response: Information only; no action is required.
816f0108-0a02ffff
[PowerSupplyElementName] has returned to OK status.
Explanation: IMM has detected that Power Supply 2 has returned to a normal operational status.
May also be shown as 816f01080a02ffff or 0x816f01080a02ffff
Severity: Info
Alert Category: Critical - Power
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0087
SNMP Trap ID: 4
Automatically notify Support: No
User response: Information only; no action is required.
816f010c-2581ffff
Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Explanation: IMM has detected a recovery from an uncorrectable memory error.
May also be shown as 816f010c2581ffff or 0x816f010c2581ffff
Severity: Info
Alert Category: Critical - Memory
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0139
SNMP Trap ID: 41
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.