IBM System x3750 M4 Installation And Service Manual page 601

Types 8722 and 8733
Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

80070603-2B01ffff
Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: IMM has detected a voltage regulator error on the microprocessor and memory expansion tray.
May also be shown as 800706032B01ffff or 0x800706032B01ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response:
v CPU 3 VRD: Indicates a problem with either the voltage regulator for CPU3 or CPU 3 itself
v CPU 4 VRD: Indicates a problem with either the voltage regulator for CPU4 or CPU 4 itself
v DIMM 25-30 VRD: Indicates a problem with either the voltage regulator for DIMMs 25-30 or 1 or more of the
following components: DIMM25-DIMM30
v DIMM 31-36 VRD: Indicates a problem with either the voltage regulator for DIMMs 31-36 or 1 or more of the
following components: DIMM31-DIMM36
v DIMM 37-42 VRD: Indicates a problem with either the voltage regulator for DIMMs 37-42 or 1 or more of the
following components: DIMM37-DIMM42
v DIMM 43-48 VRD: Indicates a problem with either the voltage regulator for DIMMs 43-48 or 1 or more of the
following components: DIMM43-DIMM48
Check the IMM Web event log. This event may be a symptom of an earlier error.
1.
Depending on the error perform the following steps.
2.
For a CPU 3 VRD or CPU 4 VRD error:
1. Replace the microprocessor and memory expansion tray.
2. Replace affected microprocessor.
For a DIMM 25-30 VRD, DIMM 31-36 VRD, DIMM 37-42 VRD, or DIMM 43-48 VRD error:
1. Replace DIMM(s) associated with error.
2. Replace the microprocessor and memory expansion tray.
80070608-2584ffff
Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: IMM has detected Power Supply related fault. (PS 12V OC Fault, PS 12V OV Fault, PS 12V UV Fault,
or PS AUX UV Fault)
May also be shown as 800706082584ffff or 0x800706082584ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response:
Check the power supply LEDs, see "Power-supply LEDs".
1.
2.
Replace the failing power supply.
80070603-2B01ffff • 80070608-2584ffff