80010701-1408ffff • 80010701-1409ffff
80010701-1408ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: IMM has detected that the temperature of a microprocessor and memory expansion tray voltage
regulator has risen above normal.
May also be shown as 800107011408ffff or 0x800107011408ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010701-1409ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: IMM has detected that the temperature of a microprocessor and memory expansion tray voltage
regulator has risen above normal.
May also be shown as 800107011409ffff or 0x800107011409ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.