8003010e-2581ffff • 80070201-0301ffff
8003010e-2581ffff
Sensor [SensorElementName] has asserted.
Explanation: IMM has detected that the memory size has changed.
May also be shown as 8003010e2581ffff or 0x8003010e2581ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0508
SNMP Trap ID:
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
80070114-2201ffff
Sensor [SensorElementName] has transitioned from normal to non-critical state.
Explanation: Trusted Platform Module (TPM) event has transitioned to non critical state.
May also be shown as 800701142201ffff or 0x800701142201ffff
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 60
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
80070201-0301ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a CPU 1 temperature Sensor has transitioned to critical.
May also be shown as 800702010301ffff or 0x800702010301ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.