80070201-0302ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a CPU 2 temperature Sensor has transitioned to critical.
May also be shown as 800702010302ffff or 0x800702010302ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070201-0303ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a CPU 3 temperature Sensor has transitioned to critical.
May also be shown as 800702010303ffff or 0x800702010303ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070201-0302ffff • 80070201-0303ffff