IBM System x3750 M4 Installation And Service Manual page 605

Types 8722 and 8733
Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

800b010a-1e86ffff
Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Fan Redundancy has been lost.
May also be shown as 800b010a1e86ffff or 0x800b010a1e86ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 6
800b010c-2581ffff
Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Backup Memory Redundancy has been lost.
May also be shown as 800b010c2581ffff or 0x800b010c2581ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 41
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
800b0208-1381ffff
Redundancy Degraded for [RedundancySetElementName] has asserted.
Explanation: Power unit is no longer in the redundant state.
May also be shown as 800b02081381ffff or 0x800b02081381ffff
Severity: Warning
Alert Category: Warning - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0804
SNMP Trap ID: 10
Automatically notify Support: No
User response:
1. Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
800b010a-1e86ffff • 800b0208-1381ffff
Appendix D. Integrated management module II (IMM2) error messages
587

Advertisement

Table of Contents
loading

Table of Contents