IBM System x3750 M4 Installation And Service Manual page 648

Types 8722 and 8733
Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

806f010d-0419ffff • 806f010d-041affff
806f010d-0419ffff
The [NumericSensorElementName] has been disabled due to a detected fault.
Explanation: The drive 25 has been disabled (defunct) due to a fault detected by the controller.
May also be shown as 806f010d0419ffff or 0x806f010d0419ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.
806f010d-041affff
The [NumericSensorElementName] has been disabled due to a detected fault.
Explanation: The drive 26 has been disabled (defunct) due to a fault detected by the controller.
May also be shown as 806f010d041affff or 0x806f010d041affff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.
630
System x3750 M4 Types 8722 and 8733: Installation and Service Guide