IBM System x3750 M4 Installation And Service Manual page 468

Types 8722 and 8733
Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

409-904-000 • 409-905-000
409-904-000
Nvidia::DiagnosticServiceProvider::Query Test Failed
Explanation: Nvidia GPU Query Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system.
2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3. Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4. Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of system issues
can cause diagnostic failure.
5. If the problem remains, contact your IBM technical-support representative.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
409-905-000
Nvidia::DiagnosticServiceProvider::Matrix Test Failed
Explanation: Nvidia GPU Matrix Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system.
2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3. Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4. Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of system issues
can cause diagnostic failure.
5. If the problem remains, contact your IBM technical-support representative.
Related Links:
v
IBM Support Website
Latest level of DSA
v
Latest level of BMC/IMM
v
450
System x3750 M4 Types 8722 and 8733: Installation and Service Guide

Advertisement

Table of Contents
loading