The [NumericSensorElementName] has been disabled due to a detected fault.
Explanation: The drive 11 has been disabled (defunct) due to a fault detected by the controller.
May also be shown as 806f010d040bffff or 0x806f010d040bffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.
806f010d-040cffff
The [NumericSensorElementName] has been disabled due to a detected fault.
Explanation: The drive 12 has been disabled (defunct) due to a fault detected by the controller.
May also be shown as 806f010d040cffff or 0x806f010d040cffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.