810b050a-1e86ffff • 816f0007-0301ffff
810b050a-1e86ffff
Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.
Explanation: Fan 6 has regained its redundancy.
May also be shown as 810b050a1e86ffff or 0x810b050a1e86ffff
Severity: Info
Alert Category: Critical - Fan Failure
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0811
SNMP Trap ID: 11
Automatically notify Support: No
User response: Information only; no action is required.
810b050c-2581ffff
Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted.
Explanation: Memory component group has regained its redundancy.
May also be shown as 810b050c2581ffff or 0x810b050c2581ffff
Severity: Info
Alert Category: Critical - Memory
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0811
SNMP Trap ID: 41
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
816f0007-0301ffff
[ProcessorElementName] has Recovered from IERR.
Explanation: IMM has detected that processor 1 recovered from an IERR condition.
May also be shown as 816f00070301ffff or 0x816f00070301ffff
Severity: Info
Alert Category: Critical - CPU
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0043
SNMP Trap ID: 40
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.