806f0207-2583ffff • 806f020d-0401ffff
806f0207-2583ffff
[ProcessorElementName] has Failed with FRB1/BIST condition.
Explanation: IMM has detected a Processor Failed - FRB1/BIST condition.
May also be shown as 806f02072583ffff or 0x806f02072583ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0044
SNMP Trap ID: 40
Automatically notify Support: Yes
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
806f020d-0400ffff
Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].
Explanation: Failure predicted (PFA) on the hard drive 0.
May also be shown as 806f020d0400ffff or 0x806f020d0400ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response: Replace the hard disk drive at the next maintenance period.
806f020d-0401ffff
Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].
Explanation: Failure predicted (PFA) on the hard drive 1.
May also be shown as 806f020d0401ffff or 0x806f020d0401ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response: Replace the hard disk drive at the next maintenance period.