80010701-1404ffff • 80010701-1405ffff
80010701-1404ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: IMM has detected that the temperature of a system board voltage regulator has risen above normal
levels.
May also be shown as 800107011404ffff or 0x800107011404ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010701-1405ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: IMM has detected that the temperature of a system board voltage regulator has risen above normal
levels.
May also be shown as 800107011405ffff or 0x800107011405ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
552
System x3750 M4 Types 8722 and 8733: Installation and Service Guide