IBM System x3750 M4 Installation And Service Manual page 481

Types 8722 and 8733
Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

166-822-001
IMM I2C Test Aborted
Explanation: Destination unavailable.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
166-823-001
IMM I2C Test Aborted
Explanation: Cannot execute command. Insufficient privilege level.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
166-824-001
IMM I2C Test Aborted
Explanation: Cannot execute command.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at a time and try the test after each action:
1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the latest level.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
166-822-001 • 166-824-001