806f0013-1701ffff • 806f0021-0b02ffff
806f0013-1701ffff
A diagnostic interrupt has occurred on system [ComputerSystemElementName].
Explanation: The user has pressed the NMI button or there has been a malfunction with the button.
May also be shown as 806f00131701ffff or 0x806f00131701ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0222
SNMP Trap ID: 50
Automatically notify Support: No
User response: If the NMI button has not been pressed, complete the following steps:
1. Make sure that the NMI button is not pressed.
2. Replace the system board (Trained service personnel only).
806f0021-0b01ffff
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Explanation: IMM has detected a Fault in PCIe slot 1.
May also be shown as 806f00210b01ffff or 0x806f00210b01ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response: Replace PCIe card
806f0021-0b02ffff
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Explanation: IMM has detected a Fault in PCIe slot 2.
May also be shown as 806f00210b02ffff or 0x806f00210b02ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response: Replace PCIe card