IBM System x3750 M4 Installation And Service Manual page 508

Types 8722 and 8733
Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

W.3818005 • W.58001
W.3818005
[W.3818005] The CRTM flash driver could not successfully flash the staging area. The update was
aborted
Explanation: CRTM Update Aborted
Severity: Warning
User response: Complete the following steps:
Continue booting sytem. If system does not reset, manually reset the system.
1.
2.
If the error is not reported on the subsequent boot, no additional recovery action is required.
3.
If the error persists, continue booting system and update the UEFI firmware.
4.
Replace the system board.
W.3938002
[W.3938002] A boot configuration error has been detected.
Explanation: Boot Configuration Error
Severity: Warning
User response: Complete the following steps:
1.
Boot to the Setup utility (F1 Setup, Load Default Settings and Save Settings) to restore all settings.
2. Attempt to configure the system again.
W.50001
[W.50001] A DIMM has been disabled due to an error detected during POST.
Explanation: A DIMM has been disabled.
Severity: Warning
User response: Complete the following steps:
1.
Check the log for any events related to memory faults and resolve those issues.
2.
Re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
3.
Restart the system.
4.
Reset the IMM to the default settings.
Reset UEFI to the default settings.
5.
Update the IMM and UEFI firmware.
6.
Replace the system board.
7.
W.58001
[W.58001] The PFA Threshold limit (correctable error logging limit) has been exceeded on DIMM
number % at address %. MC5 Status contains % and MC5 Misc contains %.
Explanation: IMM PFA Threshold Exceeded
Severity: Warning
User response: Complete the following steps:
Refer to TIP H212293 for the minimum code level.
1.
2.
If the system was recently installed, moved, serviced, or upgraded, verify that the specified DIMM is seated
properly and visually verify that there is no foreign material in any DIMM connector on that memory channel. If
either of these conditions is found, correct and retry with the same DIMM.
Note: Event Log may contain a recent 580A4 event denoting detected change in DIMM population that could be
related to this problem.
3.
Check the IBM support site for service bulletins or firmware updates that apply to this memory error.
4.
If the problem persists, replace the affected DIMM (based on the light path LEDs or event log entry) at the next
scheduled maintenance opportunity.
5.
If problem recurs on the same DIMM, swap the other DIMMs on the same memory channel across channels one
at a time to a different memory channel or processor. See the section "Installing a DIMM" in the product
documentation for population requirements for sparing/paring modes. If problem follows a moved DIMM to a
different memory channel, replace that DIMM.
490
System x3750 M4 Types 8722 and 8733: Installation and Service Guide