81010901-2d01ffff • 81010b01-1401ffff
81010901-2d01ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.
Explanation: IMM has detected that the PCH temperature has returned to a normal range.
May also be shown as 810109012d01ffff or 0x810109012d01ffff
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0495
SNMP Trap ID: 0
Automatically notify Support: No
User response: Information only; no action is required.
81010902-0701ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted.
Explanation: A previously high voltage has returned to below its specified threshold (sensor Planar 12V, Planar 3.3V,
or Planar 5V).
May also be shown as 810109020701ffff or 0x810109020701ffff
Severity: Info
Alert Category: Critical - Voltage
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0495
SNMP Trap ID: 1
Automatically notify Support: No
User response: Information only; no action is required.
81010b01-1401ffff
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
deasserted.
Explanation: IMM has detected that a system board voltage regulator temperature has returned to the normal range.
May also be shown as 81010b011401ffff or 0x81010b011401ffff
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0499
SNMP Trap ID: 0
Automatically notify Support: No
User response: Planar VR1 Temp : Information only; no action is required.