800b010a-1e83ffff • 800b010a-1e85ffff
800b010a-1e83ffff
Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Fan Redundancy has been lost.
May also be shown as 800b010a1e83ffff or 0x800b010a1e83ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 3
800b010a-1e84ffff
Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Fan Redundancy has been lost.
May also be shown as 800b010a1e84ffff or 0x800b010a1e84ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 4
800b010a-1e85ffff
Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Fan Redundancy has been lost.
May also be shown as 800b010a1e85ffff or 0x800b010a1e85ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 5