806f060d-0418ffff • 806f060d-0419ffff
806f060d-0418ffff
Array [ComputerSystemElementName] has failed.
Explanation: The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array
all member drives will report this message.
May also be shown as 806f060d0418ffff or 0x806f060d0418ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v Replace the hard disk drives that are indicated by a lit status LED.
v Recreate the array.
v Restore data from backup.
806f060d-0419ffff
Array [ComputerSystemElementName] has failed.
Explanation: The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array
all member drives will report this message.
May also be shown as 806f060d0419ffff or 0x806f060d0419ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v Replace the hard disk drives that are indicated by a lit status LED.
v Recreate the array.