IBM System x3750 M4 Installation And Service Manual page 569

Types 8722 and 8733
Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

80010701-1402ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: IMM has detected that the temperature of a system board voltage regulator has risen above normal
levels.
May also be shown as 800107011402ffff or 0x800107011402ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010701-1403ffff
Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: IMM has detected that the temperature of a system board voltage regulator has risen above normal
levels.
May also be shown as 800107011403ffff or 0x800107011403ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010701-1402ffff • 80010701-1403ffff
Appendix D. Integrated management module II (IMM2) error messages
551

Advertisement

Table of Contents
loading

Table of Contents