S.3060007
[S.3060007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for any service bulletins or firmware updates that apply to this error.
2.
Update the primary UEFI image.
3.
Replace the system board.
S.3070007
[S.3070007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity: Error
User response: Complete the following steps:
1.
Check IBM support site for any service bulletins or firmware updates that apply to this error.
2.
Update the primary UEFI image.
3.
Replace the system board.
S.3108007
[S.3108007 ] The default system settings have been restored.
Explanation: System Configuration Restored to Defaults
Severity: Error
User response: Check the IBM support site for any service bulletins or firmware updates that apply to this error.
S.3818004
[S.3818004] The CRTM flash driver could not successfully flash the staging area. A failure occurred.
Explanation: CRTM Update Failed
Severity: Error
User response: Complete the following steps:
1.
Continue booting sytem. If system does not reset, manually reset the system.
2.
If the error is not reported on the subsequent boot, no additional recovery action is required.
3.
If the error persists, continue booting system and update the primary UEFI image.
4.
Replace the system board.
S.3818007
[S.3818007] The firmware image capsules for both flash banks could not be verified.
Explanation: CRTM image capsule could not be verified
Severity: Error
User response: Complete the following steps:
If system failed to boot successfully, recycle AC power. Restart the system.
1.
If system boots to F1 setup, update the UEFI firmware and reset the bank to primary (if required). If system
2.
boots without error, recovery is complete and no additional action is required.
If system fails to boot, or if the firmware update fails, replace the system board.
3.
S.3060007 • S.3818007
Appendix C. UEFI/POST error codes
483