806f0123-2101ffff • 806f0207-0301ffff
1.
Reinsert the USB/Video cable.
2.
Replace the USB/Video cable.
806f0123-2101ffff
Reboot of system [ComputerSystemElementName] initiated by [WatchdogElementName].
Explanation: The IPMI Watchdog Timer has expired. A reboot of the system was initiated.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0370
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
806f0125-0c01ffff
[ManagedElementName] detected as absent.
Explanation: IMM has detected the Operator Information panel is absent.
May also be shown as 806f01250c01ffff or 0x806f01250c01ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Reinsert or replace the operator information panel cable.
Replace the operator information panel.
2.
806f0207-0301ffff
[ProcessorElementName] has Failed with FRB1/BIST condition.
Explanation: IMM has detected a Miroprocessor 1 Failed - FRB1/BIST condition.
May also be shown as 806f02070301ffff or 0x806f02070301ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0044
SNMP Trap ID: 40
Automatically notify Support: Yes
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
634
System x3750 M4 Types 8722 and 8733: Installation and Service Guide