806f0107-0304ffff • 806f0108-0a02ffff
806f0107-0304ffff
An Over-Temperature Condition has been detected on [ProcessorElementName].
Explanation: The microprocessor 4 temperature has risen above the critical level, causing a hard shutdown of the
node.
May also be shown as 806f01070304ffff or 0x806f01070304ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0036
SNMP Trap ID: 0
Automatically notify Support: No
User response: Complete the following steps:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the microprocessor 4 heat sink is securely installed.
5. (Trained service technician only) Make sure that the microprocessor 4 heat sink is installed correctly and the
thermal material is correctly applied.
6. (Trained service technician only) Replace microprocessor 4.
806f0108-0a01ffff
[PowerSupplyElementName] has Failed.
Explanation: IMM has detected a Fault on Power Supply 1.
May also be shown as 806f01080a01ffff or 0x806f01080a01ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: Yes
User response: Check the log for additional Power Supply Failure. Replace the Power Supply 1, if needed
806f0108-0a02ffff
[PowerSupplyElementName] has Failed.
Explanation: IMM has detected a Fault on Power Supply 2.
May also be shown as 806f01080a02ffff or 0x806f01080a02ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: Yes
User response: Check the log for additional Power Supply Failure. Replace the Power Supply 2, if needed