IBM System x3750 M4 Installation And Service Manual page 692

Types 8722 and 8733
Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

806f060d-0414ffff • 806f060d-0415ffff
806f060d-0414ffff
Array [ComputerSystemElementName] has failed.
Explanation: The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array
all member drives will report this message.
May also be shown as 806f060d0414ffff or 0x806f060d0414ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v Replace the hard disk drives that are indicated by a lit status LED.
v Recreate the array.
v Restore data from backup.
806f060d-0415ffff
Array [ComputerSystemElementName] has failed.
Explanation: The Drive is part of an RAID array that is in the failed condition. To identify drives in the failed array
all member drives will report this message.
May also be shown as 806f060d0415ffff or 0x806f060d0415ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
v Check IMM log for Predictive Fault (PFA) or other hard drive messages to help identify failing drive(s).
v Replace the hard disk drives that are indicated by a lit status LED.
v Recreate the array.
v Restore data from backup.
674
System x3750 M4 Types 8722 and 8733: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents