Accessories
11.5 DC link adapter
11.5.6.3

Cable connection and shield support

In order to simplify installing the DC link connecting cables at the DC link adapter, first fix the
cables to the control cabinet panel (also see Chapter Fixing cables to the control cabinet
panel (Page 675)).
Required tools:
● Size 6 Allen key to attach the cables
● Suitable tool for hose clamps, e.g. flat-bladed screwdriver
Table 11- 24 Connecting the DC link connecting cables to the DC link adapter
1. Fix the first core of the DC link connecting
1.
cable to the profile rail using a cable clamp.
3. Slide the cable clamp onto the tongue, and
3.
then insert the end of the cable into the DCN
3.
connection of the DC link adapter.
676
2. Route the cable end through an appropriate
2.
cable clamp.
4. Tighten the cable using an Allen key.