11.8

Spacing bolt for Booksize Compact components

To increase the mounting depth of modules in Booksize Compact format, use spacing bolts
(order number: 6SL3462-1CC00-0AA0). In this way, it is possible to combine modules in
Booksize Compact format directly with booksize modules with internal air cooling.
Table 11- 28 Number of spacing bolts and holes for various module widths
Module width in [mm]
50
75
100
Mounting the spacing bolts with press-in nuts
● Inserting M6 press-in nuts into the mounting panel
● Distance 25 mm ± 0.15 mm for module width 75 mm
● Distance 50 mm ± 0.15 mm for module width 100 mm
Figure 11-43 Mounting the M6 press-in nuts on the rear of the mounting panel
As an alternative to press-in nuts, you can secure spacing bolts with M6 nuts to the rear of
the mounting panel.
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Number of spacing bolts
2
4
4
M6 press-in nuts
Mounting wall
11.8 Spacing bolt for Booksize Compact components
Number of holes/press-in nuts
2
4
4
Accessories