Siemens Sinamics S120 Manual page 172

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Line Modules Booksize
4.2 Active Line Modules with internal air cooling
Internal air cooling
Rated power
DC link currents
Rated DC link current:
for 600 V:
DC link current:
for 600 V DC; for S6 - 40 %
for 600 V DC; peak current
Current carrying capacity
DC link busbar:
24 V busbar:
Electronics current drawn
at 24 V DC
Total power loss
(including electronics losses, see
Power loss tables (Page 781))
Max. ambient temperature
without derating
with derating
DC link capacitance
Active Line Module
Drive line-up, max.
Power factor
Circuit breaker
(IEC 60947 and UL)
Rated short-circuit current
SCCR
3)
Cooling method (internal air cooling)
Sound pressure level
Cooling air requirement
Max. permissible heat sink
temperature
Weight
The specified power ratings apply to the line voltage range from 380 V to 480 V.
1)
Default for 400 V line systems; undervoltage trip threshold is adjusted to the parameterized rated voltage
2)
The resulting rated short-circuit current is obtained from the combination of the fuse or circuit breaker – and the Line
3)
Module in the drive system.
172
6SL3130–
7TE28–0AAx
kW
80
A
134
DC
A
176
DC
A
218
DC
A
200
DC
A
20
DC
A
1.4
DC
W
1383.6
° C
40
° C
55
μF
2820
μF
20000
cosϕ
1
See Section Overcurrent protection using line fuses and circuit
breakers (Page 51)
kA
65
Mounted fan
dB(A)
< 73
m
/h
520
3
° C
70
Rated voltage for rated data 3 AC 380 V
kg
23
7TE31–2AAx
120
200
244
292
200
20
1.8
2243.2
40
55
3995
20000
1
65
Mounted fan
< 73
520
75
23
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6