Line Modules Booksize
4.6 Basic Line Modules with internal air cooling
4.6.6

Installation

The Basic Line Modules are designed for installation in the control cabinet. They are fixed to
the control cabinet panel or a mounting panel using M6 screws.
Figure 4-54
Tightening torques:
● Firstly, tighten the nuts by hand.
Tightening torque: 0.5 Nm
● Then tighten the nuts in the specified sequence.
Tightening torque: 6 Nm
244
Control cabinet panel/mounting panel
Washer
M6 screw
Mounting a Basic Line Module with internal air cooling (example: 100 kW)