Meaning Of Leds - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Motor Modules Booksize
6.2 Motor Modules with internal air cooling
6.2.4

Meaning of LEDs

Table 6- 6
Meaning of the LEDs on the Motor Module
Status
RDY
DC LINK
Off
Off
Green
--
Orange
Red
Orange
Orange
Red
--
Green/red (0.5
--
Hz)
Green/red (2
--
Hz)
Green/orange
--
or
red/orange
See SINAMICS S120/S150 List Manual for the parameters to activate the recognition of components via LED
1)
Danger of death when live parts of the DC link are touched
Irrespective of the state of the LED "DC LINK", hazardous DC link voltages can be present.
This means the touching of live parts can result in death or serious injury.
• Observe the warning information on the component.
378
The electronics power supply is missing or outside the
permissible tolerance range.
The component is ready for operation. Cyclic DRIVE-
CLiQ communication is taking place.
The component is ready for operation. Cyclic DRIVE-
CLiQ communication is taking place.
The DC link voltage is present.
The component is ready for operation. Cyclic DRIVE-
CLiQ communication is taking place.
The DC link voltage is outside the permissible tolerance
range.
DRIVE-CLiQ communication is being established.
At least one fault is present in this component.
Note:
The LED is driven irrespective of the corresponding
messages being reconfigured.
Firmware is being downloaded.
Firmware download has been completed. The system
waits for POWER ON.
Component recognition via LED is activated
Note:
Both options depend on the LED status when
component recognition is activated.
WARNING
Description, cause
Remedy
Check the line supply
voltage.
Resolve and acknowledge
the fault.
Carry out a POWER ON.
.
1)