Connecting A Direct Measuring System; Combined Use Of Motion-Connect 500 And Motion-Connect 800Plus - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Cabinet design and EMC Booksize
12.8 Connection systems
12.8.1.6

Connecting a direct measuring system

The various options of connecting a direct measuring system with DRIVE-CLiQ ASIC and
M12 plug via MOTION-CONNECT cables to a DRIVE-CLiQ component are shown in the
following diagram.
1. Direct connection via the basic cable
2. Basic cable and 1-2 extensions
3. Basic cable, cabinet bushing and a maximum of one extension
I
II
Figure 12-25 Connecting a direct measuring system with M12 plug to a DRIVE-CLiQ component with
12.8.1.7

Combined use of MOTION-CONNECT 500 and MOTION-CONNECT 800PLUS

In principle, MOTION-CONNECT 500 cables and MOTION-CONNECT 800PLUS cables be
used together.
Basic cables and extensions for MOTION-CONNECT cables with DRIVE-CLiQ connector
and M12 socket can be combined without any restrictions.
For the combined use of MOTION-CONNECT cables with DRIVE-CLiQ connectors, the
conditions below apply.
736
M12 socket (IP67) connected to a MOTION-CONNECT DRIVE-CLiQ signal cable
M12 plug (IP67) connected to a MOTION-CONNECT DRIVE-CLiQ signal cable
M12 plug (IP67) connected to a third-party measuring system
DRIVE-CLiQ cabinet bushing M12
Basic cable
Extension
RJ45 socket (IP20)
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6