11.3.4

Removing the DC link busbars

Required tools:
● Torx screwdriver T20 for DC link screws (Torx slot)
Table 11- 12 Removing the DC link busbars
Remove the installed DC link bridges and busbars, starting
at the second component.
Do not remove the DC link bridge and the busbars of the
first component.
Remove the DC link busbar of the component.
Release the screws and remove the DC link bridges and
busbars at all of the other components.
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Loosen the screws and remove the installed DC link bridge
of the component.
View with the DC link busbars removed
Accessories
11.3 Reinforced DC link busbars